-40%

Hi-accuracy 0.05% Thermocouple Calibrator Output R S B E K J T N & DC -10mV-1.1V

$ 137.28

Availability: 10 in stock
  • Condition: New
  • Restocking Fee: No
  • Return shipping will be paid by: Buyer
  • Model: VC02
  • Item must be returned within: 30 Days
  • All returns accepted: Returns Accepted
  • Refund will be given as: Money Back
  • Country/Region of Manufacture: China
  • Brand: VICTOR
  • MPN: VC02

    Description

    Note: we'll ship this item via
    Epacket to US
    , usually the delivery time is about
    3 weeks
    ;
    For other countries, we'll ship it via
    registered air mail of Post
    ,
    usually the delivery time is about
    40-50 days
    .
    If you want express mail service, please contact us for extra postage in advance.
    Features:
    1. The basic accuracy for measurement and output is 0.05%, display 5 digits.
    2. Measurement function: DC voltage, thermocouple.
    3. Output function: DC voltage, thermocouple.
    4. 8 thermocouple types.
    5. Auto cool-end compensation when output thermocouple.
    6. C or F display.
    7. 9V battery (not included), battery life is about 25 hours
    8. Operation temperature: 0-50C; Humidity<=80%RH
    9. Storage temperature: -10C to 55C; Humidity<=90%RH
    9. Size: about 200x100x40mm
    10. Weight: 550g
    11. Accessories: test leads, PDF manual
    Specifications:
    Output
    Range
    Output range
    Resolution
    Accuracy
    Voltage
    100mV
    -10.00 ~110.00mV
    0.01mV
    ±0.05% Setting value +30uV
    The max. output current ±5mA
    1000mV
    -100.00~1100.0mV
    0.1mV
    ±0.05% Setting value ±0.3mV
    Thermocouple
    R
    -40~1760

    1

    ±0.05% Setting value ±3

    (≤100

    )
    Adopt the ITS-90 temperature
    S
    -20~1760

    1

    ±0.05% Setting value ±2

    (

    100

    )
    standard (Note 1)
    B
    400~1800

    1

    ±0.05% Setting value ±3

    (400~600

    )
    ±0.05% Setting value ±2

    (

    600

    )
    E
    -200.0~1000.0

    0.1

    ±0.05% Setting value
    ±2

    (≤-100

    )
    K
    -200.0~1370

    0.1

    J
    -200.0~1200.0

    0.1

    ±0.05% Setting value
    T
    -200.0~400.0

    0.1

    N
    -200.0~1300.0

    0.1

    ±1

    (

    -100

    )
    Measurement
    Range
    Output range
    Resolution
    Accuracy
    Voltage
    100mV
    -10.00 ~110.00mV
    10uV
    ±0.05% Measuring value ±30uV
    Input Resistance 1MΩ
    Thermocouple
    R
    -40~1760

    1

    ±0.05% Measuring value ±3

    (≤100

    )
    xInput tesistance1MΩ x
    S
    -20~1760

    1

    ±0.05% Measuring value ±2

    (

    100

    )
    Adopt the ITS-90
    B
    400~1800

    1

    ±0.05% Measuring value ±3

    (400~600

    )
    ±0.05% Setting value ±2

    (

    600

    )
    temperature standard
    E
    -200.0~1000.0

    0.1

    ±0.05% Measuring value
    (Note 3)
    ±2

    (≤-100

    )
    K
    -200.0~1370

    0.1

    J
    -200.0~1200.0

    0.1

    ±0.05% Measuring value
    T
    -200.0~400.0

    0.1

    N
    -200.0~1300.0

    0.1

    ±1

    (

    -100

    )
    Note:
    1. Not including the accuracy of inner temperature compensatory transducer.
    The range of inner temperature compensatory transducer:-10-50°C, compensatory error ≤0.5°C.
    2. Temperature coefficient

    ±0.005%

    range/°C(0°C-18°C,28°C-50°